Temporary Traffic Lights

Categories
Newsletter
Email:         
1st Name:   
2nd Name:  
Company:   
Temporary Traffic Lights
Temporary Traffic Lights
€0 per day Plus VAT
€1 per week Plus VAT
Brand: Manufacturer
Product Code: TSS IR 400
Availability: In Stock
 

These traffic lights are used when road works are taking place. These are portable and easy to set up. 

Temporary Traffic Light IR 400 LED

Model STFCIR200A

Autonomy Twenty days with the same battery 12V-220V/H to a temperature of 200C
Reduce The Maintence cost                   LED can last more than 100,000 hours                       
An easier management for your traffic lights                                    Every Light is Identicle                               
Easier Work No cables link both traffic lights
  Mobile Module, no mechanical connections
  East to move and to handle
Protection Every traffic light is programmed with a
  code, so modules cannot communicate
  between them after the verification
  Impossible to steal
  Anti theft device
Structure Head of traffic lights are in ABS,
  polycarbonate lens
  Telescopic pole: close 1.65 m
                           open 2.6 m
  Battery box with wheels 520 x 390 x 330
                                     ( L x I x H )
  Weight without battery 45kg per light
  Power Supply 12 V - 220 V A/H
   

Directions for use traffic light IR 400

1. Presentation

A traffic light set is composed of 2 heads of traffic lights, 2 batteries box with wheels, 2 operating modules allow the program definition; a mobile module records parameters on one of command module to program the second one.

2.General Rules

Put into every box

  • A battery 12 V-220 A/H
  • A power supply 220 / 12V
  • Install telescopic pole in the higher position.

When you put power supply if synchronisation procedure has not been executed, then middle light is in the blinking orange.

3.Synchronisation Procedure

Going to one of the traffic lights with the mobile module.

  • Press the button: “marche” (Run); the red pilot light works.
  • Bring the mobile module near to LCD display (fourth light).
  • Possible programming only if the red pilot light M/A (Run / Stop) blinks.
  • To program the road works length and traffic density
  • Press buttons: “length” and “traffic”
  • Verify data that you want program on your LCD display.
  • Press the “VALID” button (red pilot light works), this action sanction the fire cycle.

NB: A buzzer signals every action on buttons.

Going to the second temporary traffic light.

  • Bring the mobile module near to LCD display (fourth optic)
  • Press the “VALID” button.
  • The traffic light self-programming sanctions the cycle, the module stop working automatically.
  • After validation you can verify the cycle on LCD display.

NB: A buzzer signals that programming has been executed.

Carefully

  • You have 20 minutes to execute this operation, after 20 minutes the mobile module is stopped automatically.
  • The LCD display lighting stops itself after 20 minutes; cycle and battery power supply always appears on LCD display.

4.Functioning Mode

Pressing the “Mode” button (this button is into the battery box) allows finding other functions.

  • Stand by: Lights not work
  • Blinking: orange light blinking
  • Red Only: Light blocked to the red

The communication on one or other mode does not bring about perturbation on the synchronisation.

5. Information Failures

Defects appear on the LCD display, 2 x 16 types and are listed in 3 different categories:

Defects cancelling the synchronisation with the orange light blinking

  • Time base defect

Two sort batteries defect:

  • Medium power: blinking orange light
  • Low power: stand by (not light sign)

Transmission defect between the remote control infrared module and Module MTI 400.

  • Defects do not bring about the loss of synchronisation, return to pre-programmed cycle when defects disappear.
  • Defects light bulb
  • Defects in the main battery (cycle preservation during 8 hours)
  • Defects on account of manipulation error (Module not programmed)

6. Stop Temporary Traffic Light

To stop a temporary traffic light or to reset: stop the power supply and press the mode button between 5 seconds (this button is into the battery box)

If you stop the power supply without pressing the button, you will hear a buzzer.

Carefully

  • If you have any programming problems with mobile module verify if the 9 Volts accumulator works.
  • If you have power supply a problem, verify the fuse (fuse 5 x 20 2A) in to the battery box.
  • You cannot program in a second time the other traffic light without cancelled its cycle.

Categories
Newsletter
Email:         
1st Name:   
2nd Name:  
Company:   
Copyright Hire Here LTD, 159 South Circular Road, Dublin 8 | Site by Greenlight